Pennsylvania Survival Products Country Store


Page 1 2 3
Aqua Star Designed to last a lifetime
COMMERCIAL APPLICATIONS:
In Commercial applications requiring high temperatures and high volumes of heated water,the capability exists to produce a maximum temperature of 180ºF at 2 gallons per minute or 4.5 gallons per minute at 115ºF

RESIDENTIAL:
Residential needs are also met where larger volumes are required. For example, the Model 170 can fill a 100 gallon Whirlpool in less than 20 minutes and still supply an endless quantity of hot water for any other household uses.

ENERGY SAVING:
AquaStar tankless water heaters operate differently than conventional tank type water heaters. Energy savings up to 5001o are realized due to the elimination of the need to store any hot water at all. AquaStar will deliver a continuous flow of hot water at a given temperature within the flow rate specifications (see specification chart).

CHOOSING:
It is important to choose the right AquaStar model for your application. Tankless water heaters if sized correctly will do the job effectively and efficiently for many years to come. If you need help in choosing the right model or have questions about installation or sizing, ask your local dealer.

Model "S" Series Heaters:
All Aquastar Models are available with special gas valve assembly designed specifically for installations where inlet water will be preheated.
Perfect for backup to solar system.
Add an "S" to the model number when ordering

SPECIFICATIONS
MODEL 170
Model 125
Model 80
Power Btu Input
56,000 to 165,000
25,000 to 125,000
Thermostatically variable
25,000 to 77,500
** LP Gas Pressure
11" W.C.
11" W.C. Minimum
10" W.C. Minimum
** Natural Gas Pressure
7" W.C.
7" W.C. Minimum
5" W.C. Minimum
Recovery Time
176 gallons/hour
126 gallons/hour
90º water temperature rise
78 gallons/hour
Gallons per minuet @
50ºF Temp Rise (105ºF)*
60ºF Temp Rise (115ºF)*
70ºF Temp Rise (125ºF)*
 90ºF Temp Rise (145ºF) *
5.3 GPM
4.40 GPM
3.77 GPM
2.95 GPM
3.8 GPM
3.25 GPM
2.85 GPM
2.11 GPM
2.3 GPM
1.80 GPM
1.67 GPM
1.30 GPM
Minimum Flow to Activate Burners
1.1 GPM 3/4 GPM 3/4 GPM
Vent Size
6" 5" 4"
Water Connections
3/4" NPT Thread Male 1/2" Sweat Copper 1/2" Sweat Copper
Gas Connections
3/4" NPT Thread Male 3/4" Thread 3/4" Thread
Minimum Water Pressure
15 psi 15 psi 15 psi
Maximum Water Pressure
150 psi 150 psi 150 psi
Height x Width x Depth
35-1/2" x 22-1/2" x 13-1/2" 27-1/2" x 17" x 9-1/2" 27-1/2" x 12" x 9-1/2"
Net Weight
66 lbs 37 lbs 28 lbs
Shipping Weight
75 lbs 43 lbs 32 lbs
 *ASSUMES 55'F INLET TEMPERATURE.                                              SPECIFICATIONS SUBJECT TO CHANGE
**GAS PRESSURE SUPPLIED LOWER THAN THE REQUIRED MINIMUM WILL RESULT IN LOWER WATER                                                       TEMPERATURES.

 Page 1 2 3